Premium Trickle Vent - Slot/Frame Vent for uPVC Window 400mm - White 5 Pack

£9.9
FREE Shipping

Premium Trickle Vent - Slot/Frame Vent for uPVC Window 400mm - White 5 Pack

Premium Trickle Vent - Slot/Frame Vent for uPVC Window 400mm - White 5 Pack

RRP: £99
Price: £9.9
£9.9 FREE Shipping

In stock

We accept the following payment methods

Description

If you are installing new vents to comply with gas or building regs then please ensure that you are familiar with the requirements for airflow. All vents are provided with two cover caps to disguise the screws and finish off the installation by simply pushing into place. When you take the existing vent off the window you will see a slot or two slots cut through your window. When fitted with the Trimvent 4000 Canopy, this vent provides an Equivalent Area (EA) of up to 2600mm².

It is recommended that you screw the vent down into position using a hand screwdriver not a drill or any other mechanically/electrically operated device. The screws will appear quite tight but this is important to cut a suitable thread into the plastic. Provided you don’t over-tighten the screws the vent will be adequately fixed.

Trimvent ventilators have been specified and fitted on millions of windows throughout the UK and mainland Europe for 25 years. The range of vents are manufactured by Titon™ from aluminium giving your window a high-end feel. Ideal for use on new build properties or window refurbishment projects in existing properties and suitable to be used on timber, aluminium, or PVCu windows.

Challenge: Including these additional ventilation components requires adjustments in manufacturing processes, sourcing of new materials, and compliance with quality standards. These factors contribute to higher production costs, which may ultimately be passed on to consumers, causing dissatisfaction. We should point out that there may also be extra difficulty with uPVC if there is a metal reinforcement section inside the hollow profile of the frame. This can be the case but not always and the metal can be either aluminium or galvanised steel. The metal sections tend to be quite thin but the galvanised surface of steel is difficult to drill through. Once your item has been returned, we will inspect it and take the necessary action as soon as possible. Take the window out of the frame if it is easier particularly if you decide the vent is the best option to place the vent otherwise it will be done in the head of the window where there is no interference from the glass. The new vent may contain a series of lugs that need to go inside the slot in your window. It is most likely that the new vent is too big for the slot and you need a narrower vent or you will need to slice the lugs off with a sharp knife (Stanley type).It has been specifically developed for recent revisions to Part F of the Building Regulations for Ventilation (England & Wales), is optimised for use with the Scottish Technical Standards, and to improve performance for requirements throughout the UK and Europe. The overall length of the slot against the screw fixing points size (ensure there is enough room past the slot at each end to get a screw into the frame. The windows you have will require slots cutting through them that are the correct dimensions. By drilling holes this will not allow enough air through because of the bridges between the holes. The basis of these window ventilators is to pass air through the frame and to do this you will need to form a slot within the tolerances shown. This can be done on uPVC or timber windows but aluminium or steel windows is not advisable. The vents can then be screwed to the frame and operated quite simply.



  • Fruugo ID: 258392218-563234582
  • EAN: 764486781913
  • Sold by: Fruugo

Delivery & Returns

Fruugo

Address: UK
All products: Visit Fruugo Shop